OPTIFLUX 6000
The OPTIFLUX 6000 is an electromagnetic flowmeter (EMF) for hygienic applications in the food sector. The 3A and EHEDG certified flowmeter has industry-specific insertion lengths to meet the stringent requirements of the food and beverage industry.
Categories: Flow, Flow measuring devices
Technical data
| General technical data | |
|---|---|
| Measuring principle | Magnetic-inductive |
| Nominal widths | DN 2.5 to DN 150 |
| Accuracy | Up to 0.3 % of the measured value |
| Medium temperature | Up to 140 °C |
| Process connection | DIN 11851, Tri-Clamp |
| Lining | PFA |
| Ambient temperature | Up to 65 °C |
| Protection type | IP66/IP67, IP69 for stainless steel case |
| Outputs | Analog output (4 to 20 mA) with HART and pulse/frequency/status |
| Display | LCD display, white backlight for displaying up to 3 measured values |
| Special features | EHEDG and 3A approval; optional stainless steel case |