Integrated field-oriented control drive Series DRVI
For stepper and brushless DC, Nema 23 and Nema 24 motors
The Series DRVI integrated motor drive is designed to control various types of motors, both stepper and brushless, using a closedloop control (FOC) algorithm.
This algorithm, also known as vector control (FOC), offers better performance than traditional stepper motor control systems, which allows the stepper motor to operate over the entire speed range, ensuring fast acceleration and deceleration, assuring more accurate motion control with no loss of steps.It is also more energy efficient than traditional control methods, as it uses precise rotor position feedback and controls the phase current, optimising motor operation.
Its compact design and integration with the main communication protocols make the Series DRVI the ideal solution for various industrial applications that require accurate control and fast response to load variations.
This algorithm, also known as vector control (FOC), offers better performance than traditional stepper motor control systems, which allows the stepper motor to operate over the entire speed range, ensuring fast acceleration and deceleration, assuring more accurate motion control with no loss of steps.It is also more energy efficient than traditional control methods, as it uses precise rotor position feedback and controls the phase current, optimising motor operation.
Its compact design and integration with the main communication protocols make the Series DRVI the ideal solution for various industrial applications that require accurate control and fast response to load variations.
Categories: CAMOZZI, Drives, Electric Actuation
General Data
| DRVI-23ST012-.. | DRVI-24ST022-.. | DRVI-24EC125-.. | |
| Motor type | Stepper | Stepper | Brushless DC |
| Flange size | NEMA 23 | NEMA 24 | NEMA 24 |
| Power supply | 24 – 48 VDC | 24 – 48 VDC | 24 – 48 VDC (nominal 48 V) |
| Logic supply | 24 VDC | ||
| GPIO (General-purpose input/output) | 2 digital inputs, for sensors (homing and extra-stroke) 2 general digital inputs 1 general digital output | ||
| IP protection class | IP65, except motor shaft (caps must be fitted to unused connectors to ensure IP protection) | ||
| Control loop | Closed loop by field-oriented control (FOC) | ||
| Operation mode | Position Speed Torque (available only for brushless version DRVI-24EC) | ||
| Communication protocol | Profinet CANopen EtherCAT EtherNet/IP | ||
| Additional function | STO (Safe Torque Off), PLd, SIL 2, EN 61800-5-2 | ||
| Rated speed [rpm] | – | – | 3000 |
| Max speed [rpm] | 3000 | 3000 | 3000 |
| Rated torque [Nm] | – | – | 0,5 |
| Peak torque [Nm] | – | – | 1,5 |
| Torque at 0 rpm at 24VDC [Nm] | 1,2 | 2,2 | – |
| Torque constant Kt [Nm/A] | – | – | 0,105 |
| Rated power [W] | – | – | 125 |
| Rotor inertia [kg cm2] | 0,38 | 0,78 | 0,91 |
| Permissible radial load at the end of the shaft [N] | 50N | 60N | 60N |
| Weight [kg] | 1,1 | 1,6 | 1,1 |
| Weight with Brake [kg] | 1,85 | 2,35 | 1,85 |
| Encoder type | Absolute single turn | ||
| Recommended motor inertia ratio | <1:10 | ||
| Current Consumption [A] | 3,5 A | ||
| Current Consumption, logic [A] | <0,07A | ||
| Current Consumption with Brake [A] | 0,1A | ||
| General digital Input IN1, IN2 | Isolated, compliant with IEC 61131-2 type 3 | ||
| Sensor digital input Homing, External | Isolated input, differential, 24V | ||
| General digital output | Protected isolated input, maximum 400mA <0,2 | ||
| Maximum auxiliary current 24VDC [A] | <0,13 A | ||
| Protection | I2T, overvoltage, overcurrent, overtemperature | ||
| Operating temperature [°C] (no icing) | -20°C / + 50°C for stepper version (DRVI-23ST.., DRVI-24ST..) must be considered a derating on nominal torque, over 30°C | ||
| Humidity [%] (no condensing) | 15% – 90% | ||
| Installation max altitude [m] | 1000 | ||
| Vibration resistance | IEC 60068-2-6, IEC 60068-2-64 | ||
| Shock resistance | IEC 60068-2-27 | ||
| Brake resistance | Not present | ||
| BRAKE OPTION | |||
| Holding torque [Nm] | 1,5 Nm | ||
| Opening time [ms] | <=40 ms | ||
| Closing time [ms] | <=60 ms | ||
| Maximum single switching energy [J] | 115J | ||
| Service life, operating energy [J] | 23000J | ||
Coding Example
| DRVI | – | 23 | ST | 012 | – | 0 | E | – | PN | SF |
| DRVI | SERIES |
| 23 | MOTOR FLANGE 23 = Nema 23 24 = Nema 24 |
| ST | MOTOR TYPE ST = Stepper EC = Brushless DC |
| 012 | MOTOR TORQUE 012 = 1,2 Nm (Nema 23) 022 = 2,2 Nm (Nema 24) 125 = 125 W (Only for EC) |
| 0 | MOTOR BRAKE 0 = Without brake B = With brake |
| E | MOTOR FEEDBACK E = Absolute single turn encoder |
| PN | COMMUNICATION PROTOCOL PN = Profinet CO = CanOpen EC = EtherCAT EI = EtherNet/IP |
| SF | SAFETY FUNCTION = Standard SF = Safe torque off (PLd, SIL 2, EN 61800-5-2) |
Download
– Certification_STO_DRVI_Rev_2.pdf
– EU_declaration_of_conformity_DRVI_(NO_STO).pdf
– EU_declaration_of_conformity_DRVI_(STO).pdf
– REACH-Series-DRVI.pdf