JUMO meroVIEW
The multifunctional digital controller impresses with the individual design of its user interface and hardware equipment. Analog and digital inputs and outputs, counting inputs, as well as interfaces can be flexibly added to display the required process variables. The indicator masters even complex applications with math and logic functions as well as the implementation of control functions via ST code.
Categories: Digital indicators, Digital indicators, Digital indicators, Digital indicators, Flow, Level, Pressure, Temperature
Customer benefits at a glance
Different formats offer optimum configuration for the required application
High degree of flexibility in the application areas due to a large number of inputs
High degree of flexibility in the application areas due to a large number of outputs
Easy integration into superordinate and subordinate systems possible
Less time required during startup and operation due to individualization of the device menu
Technical data
| general technical data | |
|---|---|
| Inputs | Analog input, digital input; optional: additional analog, digital, and counting inputs (12,5 kHz) |
| Outputs | 2 relays (normally open contact); optional: additional analog outputs, relays (normally open contact, changeover contact) solid state relays, logic outputs (0/14 V or 0/24 V) and open collector outputs |
| Formats | 116: 48 × 48 mm; 108H: 48 × 96 mm; 108Q: 96 × 48 mm; 104: 96 × 96 mm |
| Interfaces | USB host, USB device (setup); optional: RS485 (Modbus RTU master/slave), Ethernet (Modbus TCP master/slave), PROFINET device |
| Display | 2 LCD displays with 18 segments each including display of texts (not with JUMO meroVIEW 116), plain text display for menu, parameters, and process information |
| Connections | Removable terminal strips with PUSH IN |
| Special features | Individual design of operating levels; modular design with option cards; fast hardware counters (12,5 kHz); min. and max. value memory, hold and taring function for measured values, logic outputs (24 V and 14 V) can also be used as voltage supply for two-wire transmitters; startup delay after power-on, reset function for min. and max. values and for taring function |