Pressure regulators Series MD
Versions: single, combined with other functions, Manifold
The by-pass valve allows the fast exhaust of the air introduced.
The different springs enable a more accurate adjustment of the pressure.
The Series MD offers multi-sector solutions that ensure saving in terms of installation time, space and costs.
Thanks to the solution adopted for the pneumatic connection, it is possible to equip the same element with interchangeable cartridges that can either be threaded, or with an integrated super-rapid fitting, both types available in different sizes. Intermediate cartridges can be also integrated to join multiple functions or with derivation to draw air.
General Data
| Construction | Modular, compact wiht pre-formed diaphragm |
| Ports | With interchangeable cartridges: 1/8, 1/4 and 3/8 threaded or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm |
| Fixing | In-line Wall-mounting by means of through holes in the body or with a support bracket Panel mounting |
| Working temperature | -5°C ÷ 50°C up to 16 bar |
| Inlet pressure | 0 ÷ 16 bar |
| Outlet pressure | 0,5 ÷ 2 bar 0,5 ÷ 4 bar 0,5 ÷ 7 bar 0,5 ÷ 10 bar |
| Overpressure exhaust | With relieving Without relieving |
| Fluid | Air comprimé |
Coding Example
| MD | 1 | – | R | T | 0 | 0 | – | 1/4 |
| MD | SERIES |
| 1 | SIZE 1 = 42 mm |
| R | TYPE OF REGULATOR R = Pressure regulator M = Manifold pressure regulator |
| T | OPERATING PRESSURE (1 bar = 14,5 psi) 0 = 0,5 ÷ 10 bar 2 = 0,5 ÷ 2 bar 4 = 0,5 ÷ 4 bar 7 = 0,5 ÷ 7 bar T = Calibrated ** B = Locked ** |
| 0 | DESIGN TYPE 0 = With relieving 1 = Without relieving 2 = With relieving and by-pass valve (only for R regulator) 3 = Without relieving, with by-pass valve (only for R regulator) |
| 0 | PRESSURE GAUGE 0 = Without pressure gauge (with 1/8 port) |
| 1/4 | PORTS (IN – OUT) * = Without cartridges 1/8 = G1/8 1/4 = G1/4 3/8 = G3/8 6 = Tube Ø6 8 = Tube Ø8 10 = Tube Ø10 |
Example: MD1-R020-1/4-10.
** If the regulator is calibrated or locked, after the ports add the inlet pressure “■” and the outlet pressure “●”
INLET PRESSURE: ■ = Enter the SUPPLY pressure value
OUTLET PRESSURE: ● = Enter the OUTLET pressure value for the LOCKED regulator or the maximum value of the ADJUSTABLE pressure for the CALIBRATED regulator
Example of a calibrated regulator with Inlet Pressure = 6,3 bar and Outlet Pressure = 4,5 bar
Complete part number: MD1-RT00-1/4-6,3-4,5.