Direct acting solenoid valves Series PL
2/2-way – Normally Open (NO)
3/2-way – Normally Closed (NC) and Normally Open (NO)
3/2-way – Universal (UNI)
3/2-way – Normally Closed (NC) and Normally Open (NO)
3/2-way – Universal (UNI)
Series PL directly operated mini-solenoid valves are available in the NO version and can be mounted on single bases or on manifolds.
Please note that all Series PL solenoid valves are supplied with direct current (DC).
To operate in alternating current (AC), it is necessary to use the connector with bridge rectifier Mod. 125-900.
General Data
| TECHNICAL FEATURES | |
| Function | 2/2 NO – 3/2 NC – 3/2 NO – 3/2 UNI |
| Operation | Direct acting poppet type |
| Pneumatic connection | On subbase |
| Orifice diameter | 0.8 … 1.6 mm |
| Flow coefficient kv (l/min) | 0.30 … 0.62 |
| Operating pressure | 0 ÷ 3.5 … 10 bar |
| Operating temperature | 0 ÷ 50 °C (FKM) / -50 ÷ 50 °C (low temperature NBR on demand) |
| Fluid | Filtered air, class [5:4:4] according to ISO 8573-1 (max oil viscosity 32 cSt), inert gas |
| Response time | ON <10 ms – OFF <15 ms |
| Manual override | Mono/bistable – PBT 3/2 versions only |
| Installation | In any position |
| MATERIALS IN CONTACT WITH THE MEDIUM | |
| Body | Brass – PBT – PPS |
| Seals | FKM – NBR – EPDM (on demand) |
| Internal parts | Brass – stainless steel |
| ELECTRICAL FEATURES | |
| Voltage | 6 … 110 V DC – other voltages on demand |
| Voltage tolerance | ±10% |
| Power consumption | 1.2 … 2.7 W |
| Duty cycle | ED 100% |
| Electrical connection | Industrial standard connector (9.4 mm) |
| Protection class | IP65 with connector |
| Special versions available on demand |
Coding Example
| PL | 0 | 00 | – | 3 | 0 | 3 | – | PL | 2 | 3 |
| PL | SERIES |
| 0 | BODY DESIGN 0 = single sub-base (M5 only) or interface 1 = manifold – valves single side 2 = manifold – valves double side |
| 00 | NUMBER OF POSITIONS 00 = ISO 15218 or Series PD interface 01 = single base (M5 only) 02 ÷ 99 = manifold number of positions |
| 3 | NUMBER OF WAYS – FUNCTIONS 0 = manifolds or single base 9 = 2/2-way – NO A = 2/2-way – NO electric part revolved by 180° 3 = 3/2-way – NC 5 = 3/2-way – NC electric part revolved by 180° 4 = 3/2-way – NO 6 = 3/2-way – NO electric part revolved by 180° B = 3/2-way – NO IN-LINE* C = 3/2-way – NO IN-LINE* electric part revolved by 180° 7 = 3/2-way – UNI 8 = 3/2-way – UNI electric part revolved by 180° |
| 0 | VALVE PORTS 0 = ISO 15218 interface – 3/2-way B = series PD interface – 2/2-way MANIFOLD PORTS for P – PL – PN – W Series |
| 3 | ORIFICE DIAMETER B = Ø 0.8 mm 1 = Ø 1.1 mm 3 = Ø 1.5 mm (NC version with pressure 4 ÷ 8 bar only) 5 = Ø 1.5 mm 6 = Ø 1.5 mm (NC version with pressure 0 ÷ 3.5 bar only) 7 = Ø 1.6 mm |
| PL | MATERIALS PL = PBT body – FKM poppet seal – NBR other seals PF = PBT body – FKM seals SF = PPS body – FKM seals ST = PPS body – Low Temperature NBR seals (on demand) BF = nickel-planted brass body – FKM seals |
| 2 | ELECTRICAL CONNECTION 2 = industrial standard connection (9.4 mm) |
| 3 | VOLTAGE – POWER CONSUMPTION – OVERMOULDING MATERIAL 4 = 6 V DC – 1.2 W – PA 5 = 12 V DC – 1.2 W – PA 6 = 24 V DC – 1.2 W – PA 1 = 6 V DC – 2.7 W – PA 2 = 12 V DC – 2.7 W – PA 3 = 24 V DC – 2.7 W – PA 7 = 6 V DC – 1.2 W – PPS 8 = 12 V DC – 1.2 W – PPS 9 = 24 V DC – 1.2 W – PPS A = 6 V DC – 2.2 W – PPS B = 12 V DC – 2.2 W – PPS C = 24 V DC – 2.2 W – PPS E = 48 V DC – 2.2W – PPS F = 72 V DC – 2.2W – PPS H = 110 V DC – 3 W – PPS (can be combined with all PPS models) |
| FIXING = fixing screws for metal P = fixing screws for plastics | |
| MANUAL OVERRIDE = not required or not applicable T = mono/bistable (push/turn type) | |
| USE WITH OXYGEN: = Not suitable for use with oxygen OX1 = for use with oxygen – cleanliness level according to ASTM G93-03 Standard Level E |