Direct acting solenoid valves Series PL

2/2-way – Normally Open (NO)
3/2-way – Normally Closed (NC) and Normally Open (NO)
3/2-way – Universal (UNI)
Series PL directly operated mini-solenoid valves are available in the NO version and can be mounted on single bases or on manifolds.

Please note that all Series PL solenoid valves are supplied with direct current (DC).
To operate in alternating current (AC), it is necessary to use the connector with bridge rectifier Mod. 125-900.

General Data

TECHNICAL FEATURES
Function2/2 NO – 3/2 NC – 3/2 NO – 3/2 UNI
OperationDirect acting poppet type
Pneumatic connectionOn subbase
Orifice diameter0.8 … 1.6 mm
Flow coefficient kv (l/min)0.30 … 0.62
Operating pressure0 ÷ 3.5 … 10 bar
Operating temperature0 ÷ 50 °C (FKM) / -50 ÷ 50 °C (low temperature NBR on demand)
FluidFiltered air, class [5:4:4] according to ISO 8573-1 (max oil viscosity 32 cSt), inert gas
Response timeON <10 ms – OFF <15 ms
Manual overrideMono/bistable – PBT 3/2 versions only
InstallationIn any position
MATERIALS IN CONTACT WITH THE MEDIUM
BodyBrass – PBT – PPS
SealsFKM – NBR – EPDM (on demand)
Internal partsBrass – stainless steel
ELECTRICAL FEATURES
Voltage6 … 110 V DC – other voltages on demand
Voltage tolerance±10%
Power consumption1.2 … 2.7 W
Duty cycleED 100%
Electrical connectionIndustrial standard connector (9.4 mm)
Protection classIP65 with connector
Special versions available on demand

Coding Example

PL000303PL23
PLSERIES
0BODY DESIGN
0 = single sub-base (M5 only) or interface
1 = manifold – valves single side
2 = manifold – valves double side
00NUMBER OF POSITIONS
00 = ISO 15218 or Series PD interface
01 = single base (M5 only)
02 ÷ 99 = manifold number of positions
3NUMBER OF WAYS – FUNCTIONS
0 = manifolds or single base
9 = 2/2-way – NO
A = 2/2-way – NO electric part revolved by 180°
3 = 3/2-way – NC
5 = 3/2-way – NC electric part revolved by 180°
4 = 3/2-way – NO
6 = 3/2-way – NO electric part revolved by 180°
B = 3/2-way – NO IN-LINE*
C = 3/2-way – NO IN-LINE* electric part revolved by 180°
7 = 3/2-way – UNI
8 = 3/2-way – UNI electric part revolved by 180°
0VALVE PORTS
0 = ISO 15218 interface – 3/2-way
B = series PD interface – 2/2-way

MANIFOLD PORTS for P – PL – PN – W Series
2 = M5 thread – front outlets
3 = tube Ø 3 mm fittings – front outlets
4 = tube Ø 4 mm fittings – front outlets
6 = M5 thread – bottom outlets
7 = tube Ø 3 mm fittings – bottom outlets
8 = tube Ø 4 mm fittings – bottom outlets

3ORIFICE DIAMETER
B = Ø 0.8 mm
1 = Ø 1.1 mm
3 = Ø 1.5 mm (NC version with pressure 4 ÷ 8 bar only)
5 = Ø 1.5 mm
6 = Ø 1.5 mm (NC version with pressure 0 ÷ 3.5 bar only)
7 = Ø 1.6 mm
PLMATERIALS
PL = PBT body – FKM poppet seal – NBR other seals
PF = PBT body – FKM seals
SF = PPS body – FKM seals
ST = PPS body – Low Temperature NBR seals (on demand)
BF = nickel-planted brass body – FKM seals
2ELECTRICAL CONNECTION
2 = industrial standard connection (9.4 mm)
3VOLTAGE – POWER CONSUMPTION – OVERMOULDING MATERIAL
4 = 6 V DC – 1.2 W – PA
5 = 12 V DC – 1.2 W – PA
6 = 24 V DC – 1.2 W – PA
1 = 6 V DC – 2.7 W – PA
2 = 12 V DC – 2.7 W – PA
3 = 24 V DC – 2.7 W – PA
7 = 6 V DC – 1.2 W – PPS
8 = 12 V DC – 1.2 W – PPS
9 = 24 V DC – 1.2 W – PPS
A = 6 V DC – 2.2 W – PPS
B = 12 V DC – 2.2 W – PPS
C = 24 V DC – 2.2 W – PPS
E = 48 V DC – 2.2W – PPS
F = 72 V DC – 2.2W – PPS
H = 110 V DC – 3 W – PPS (can be combined with all PPS models)
FIXING
= fixing screws for metal
P = fixing screws for plastics
MANUAL OVERRIDE
= not required or not applicable
T = mono/bistable (push/turn type)
USE WITH OXYGEN:
= Not suitable for use with oxygen
OX1 = for use with oxygen – cleanliness level according to ASTM G93-03 Standard Level E

Download

Certifications