FIBERTRAC 31

Radiometric sensor for continuous level measurement

Flexible detector

Application area

The flexible detector is used on round vessels and vessels with conical outlet and is suitable for measurement of liquids, solids, slurries and suspensions. Due to its thin, flexible scintillator cross-section, FIBERTRAC 31 can be easily adapted to round vessels.

The FIBERTRAC 31 is a radiation-based sensor with flexible plastic sensing element for continuous measurement of liquids and bulk solids. It is suitable for level measurement under extreme process temperatures, in case of critical product features or aggressive products. The FIBERTRAC 31 delivers precise measuring results even under hardest application conditions.

Your benefit

  • Simple mounting on round and conical vessels through flexible detector
  • High plant availability through non-contact measurement
  • Cost saving through use of only one sensor up to 7 m measuring range
Categories: , ,

Technical specifications

Measuring range – Distance
  • 7 m [Meter – Foot]
Process pressure
  • – [Bar – kPa – psi]
Accuracy
  • ± 0.5 %
Density
  • Density
Materials, wetted parts
  • No wetted material
Threaded connection
  • Mounting from outside via supplied mounting brackets
Seal material
  • no media contact
Housing material
  • Aluminium
  • Stainless steel (precision casting)
Protection rating
  • IP66/IP67
Output
  • Profibus PA
  • Foundation Fieldbus
  • Four-wire: 4 … 20 mA/HART
Ambient temperature
  • -20 … 50 °C

Approvals

Scope
  • ATEX / Europe
  • CSA / Canada
  • FM / USA
  • EAC (GOST) / Russia
  • IEC / worldwide
  • NEPSI / China
  • INMETRO / Brazil
  • CCOE / India
  • KTL Korea
Explosion protection
  • Intrinsic safety “i”
  • Flameproof enclosure “d”
  • Dust ignition protection “t”
Overfill protection
  • WHG
SIL qualification
  • SIL2

Display & adjustment

Adjustment
  • PLICSCOM
  • PC, PACTware and DTM
  • HART-Communicator
  • Software (e. g. AMS™, PDM)
  • Bluetooth
Indication
  • Display/adjustment module PLICSCOM
  • VEGADIS 81
  • VEGADIS 82

Documentation

Product catalog

Radiometric

Product information

ProTrac

Specification sheet

FIBERTRAC 31

Four-wire: 4 … 20 mA/HART

Operating instructions

FIBERTRAC 31

Four-wire: 4 … 20 mA/HART

Supplementary instructions

Water cooling – FIBERTRAC 31

Accessory

Supplementary instructions

Air cooling – FIBERTRAC 31

Accessory