Digital pressure gauges Series PG

Possibility of a direct mounting with rear or panel connection
The new Series PG digital pressure gauges meet the need of an even more precise pressure adjustment, above all in proportional control.
Thanks to the IP65 protection class these pressure gauges are particularly suitable for applications where the highest environmental protection is required.

General Data

Vacuum PG…-VBPressure PG…-PB
Pressure unitsPsi, bar, mmHg, kPa
programmable by the user
Psi, bar, kgf/cm², MPa
programmable by the user
Rated pressure range [bar]0 ÷ -1 bar0 ÷ 10 bar
Display pressure range0.1 ÷ -1 bar-0.1 ÷ 10 bar
Withstand pressure [bar]3 bar15 bar
Repeatability [% FS]≤ ± 1% F.S. ± 1 digit≤ ± 0,2% F.S. ± 1 digit
Resolution
  kPa1
  MPa0.001
  kgf/cm²0.01
  bar0.01
  psi0.1
Indicator accuracy≤ ± 2% F.S. ± 1 digit (ambient temperature: 25 ± 3°C)
MediumFiltered air, incombustible and non-corrosive gases
Back lightYes
Sampling rate2 Hz (2 times/second)
LCD display3 ½ digit, 7 segment
ENVIRONMENT
Protection classIP65 (an air tube must be installed to maintain this grade)
Temperature [°C]Operation: 0 ÷ 50°C
Storage: -10 ÷ 60°C
(no condensation or freezing)
Relative humidityOperation/storage: 35 ÷ 85% RH
(no condensation)
VibrationsTotal amplitude 1.5mm or 10G
10Hz-55Hz-10Hz scan for 1 minute
2 hours for each direction of X, Y and Z
Shock100 m/s² (10G)
3 times for each direction of X, Y and Z
Changes due to temperature≤ ± 2% F.S. of detected pressure (25°C) within the operating temperature range
Pneumatic connections portsG1/4 – M5 or G1/8 – M5
FOR BATTERY-POWERED PRESSURE GAUGES ONLY
Battery typeCR 2032 lithium
Life1 year (5 times/day)
Low-power indicatorYes
ReplacementYes
Switch-on intervalDisplay turns off after 60 seconds
FOR PRESSURE GAUGES WITH POWER SUPPLY CABLE ONLY
Supply voltage [Vdc]From 12 to 28 V DC±10% Ripple
Power consumption10 mA
Max. voltage1000V AC in 1-min (between the casing and the cables)
Isolation resistance50 Mohm min (at 500 V DC, between the casing and the cables)
Electrical connection
for pressure gauges PG…-2Unshielded 2-pole cable, length 2 m
for pressure gauges PG…-MConnection with M8 4-pole connector

Coding Example

PG010PB1/82
PGSERIES
010BOTTOM SCALE
010 = 10 bar
001 = -1 bar
PPRESSURE RANGE
P = Pressure
V = Vacuum
BLIGHTING
B = Back light
1/8PNEUMATIC CONNECTIONS
1/8 = G 1/8 BSPP; M5
1/4 = G 1/4 BSPP; M5 (for battery-powered version only)
2ELECTRICAL CONNECTION (for version with cable only):
2 = With unshielded 2-pole cable of 2 m
M = With cable of 150 mm and M8 4-pole connector

Download