MOXA EDS-208
The EDS-208 Series supports IEEE 802.3/802.3u/802.3x with 10/100M, full/half-duplex, MDI/MDIX auto-sensing RJ45 ports. The EDS-208 Series is rated to operate at temperatures ranging from -10 to 60°C, and is rugged enough for any harsh industrial environment. The switches can be easily installed on a DIN rail as well as in distribution boxes. The DIN-rail mounting capability, wide operating temperature capability, and the IP30 housing with LED indicators make the plug-and-play EDS-208 switches easy to use and reliable.
Specifications
| Ethernet Interface | |
| Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3x for flow control |
| 10/100BaseT(X) Ports (RJ45 connector) | EDS-208: 8 EDS-208-M-SC: 7 EDS-208-M-ST: 7 Auto negotiation speed Full/Half duplex mode Auto MDI/MDI-X connection |
| 100BaseFX Ports (multi-mode SC connector) | EDS-208-M-SC: 1 |
| 100BaseFX Ports (multi-mode ST connector) | EDS-208-M-ST: 1 |
| Optical Fiber | ![]() |
| Switch Properties | |
| Processing Type | Store and Forward |
| MAC Table Size | 2 K |
| Packet Buffer Size | 768 kbits |
| Power Parameters | |
| Input Voltage | 12/24/48 VDC 24 VAC (24 VAC only for models with hardware version 2.1.1 or later) |
| Operating Voltage | 9.6 to 60 VDC 18 to 30 VAC |
| Input Current | EDS-208 Models: 12 to 48 VDC, 0.14 to 0.04 A or 24 VAC, 50-60 Hz, 0.13 A (max.) EDS-208-M-SC/EDS-208-M-ST Models: 12 to 48 VDC, 0.20 to 0.05 A or 24 VAC, 50-60 Hz, 0.21 A (max.) |
| Connector | 1 removable 3-contact terminal block(s) |
| Overload Current Protection | Supported |
| Reverse Polarity Protection | Supported |
| Physical Characteristics | |
| Housing | Plastic |
| IP Rating | IP30 |
| Dimensions | EDS-208: 40.03 x 100 x 74 mm (1.58 x 3.94 x 2.91 in) EDS-208-M-SC: 40.03 x 100 x 82.13 mm (1.58 x 3.94 x 3.23 in) EDS-208-M-ST: 40.03 x 100 x 84.1 mm (1.58 x 3.94 x 3.31 in) |
| Weight | EDS-208: 159 g (0.35 lb) EDS-208-M-SC: 166 g (0.37 lb) EDS-208-M-ST: 166 g (0.37 lb) |
| Installation | DIN-rail mounting |
| Environmental Limits | |
| Operating Temperature | -10 to 60°C (14 to 140°F) |
| Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| Standards and Certifications | |
| Safety | UL 508 EN 62368-1 |
| EMC | EN 55032/35 |
| EMI | FCC Part 15B Class A |
| EMS | IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV IEC 61000-4-5 Surge: Power: 1 kV; Signal: 0.5 kV IEC 61000-4-6 CS: 3 V IEC 61000-4-8 PFMF |
| Shock | IEC 60068-2-27 |
| Vibration | IEC 60068-2-6 |
| Freefall | IEC 60068-2-32 |
| MTBF | |
| Time | EDS-208 Models: 10,541,554 hrs EDS-208-M Models: 7,499,231 hrs |
| Standards | Telcordia (Bellcore), GB |