Service intended

This temperature switch is installed with a micro contact, and it is suitable for measuring the temperature of corrosive fluid. Dead band is fixed.

DimensionRefer to type of mounting
Repeatability±1.0 % of adjustable range
Measuring system (SAMA class ⅢB)Organic gas : 0 ~ 200 °C
Inert gas : -200 ~ 700 °C
Dead bandOne SPDT : 5 ~ 6 % of full scale
Two SPDT : 12 % of full scale
Working rangeMaximum scale value

Standard features

Location of stem and mountingBottom connection, surface, case mounting
CaseSilver gray finished aluminium
CoverSilver gray finished aluminium
Switch typeMicro switch snap action
Switch formOne SPDT or Two SPDT DPDT
CapillaryCapillary : 1.6/0.2 mm, 316SS
Armored tube : 7.5/5.5 mm, 304SS
Contact rating■ AC 125 V/250 V, 15 A and DC 30 V, 2 A
DC 125 V, 0.5 A for resistance load
■ AC 125 V/250 V, 15 A and DC 30 V, 1 A
DC 125 V, 0.05 A for inductive load
Conduit connection½” or ¾” PF
Stem8.0, 10.0 and 12.0 mm
316SS and 316L SS
Stem, process connection⅜”, ½”, ¾” PT, NPT and PF

© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.

Download

CATALOG

MANUAL

DRAWING