P631 to P632 series are designed to measure differential pressure from 30 kPa ro 1.5 MPa at Max. working pressure up to 25 MPa.P631 to P632 series are designed to control and alarm for differential pressure, providing right time to replace air and sluge filter during the process.

Nominal diameter150 mm
Accuracy±1.0% of full scale
±1.5% or ±1.6% of full scale
Scale range (MPa, kPa, bar)0~30 kPa to 0~50 kPa
0~0.1 MPa to 0~1.5 MPa
Max. Working pressure (Static pressure)25 MPa
Working temperatureAmbient : -20~65°C
Fluid : Max. 100°C
Degree of protectionEN60529/IEC529/IP56
Temperature effectAccuracy at temperature above and below the reference
temperature (20℃) will be effected by approximately
±0.5% per 10℃ of full scale

Standard features

Pressure connectionStainless steel (316SS)
ElementSingle Bellows
Stainless steel (316L SS)
CaseBlack finished aluminium
CoverBlack finished aluminium
Screwed type
WindowGlass
DialWhite aluminium with black graduations
Conduit connectionM20 x 1.5P
ContactContact rating: AC 250 V 3 A / 125 V 5 A
DC 250 V 0.2 A / 125 V 0.4 A / 30 V 4 A
Dielectric strength: AC 500 V /
MIN Type: Micro contact, One and two SPDT
PointerBlack painted aluminium alloy
Process connection¼” NPT(F)
½” NPT(F) at 3-way and 5-way manifold valve
Standard accessoriesMounting bracket for 2″ pipe
mounting with silver gray finished steel
Optional
  • Remote seal
  • Mounting bracket with 316SS for 2″ pipe mounting
  • 3-way manifold valve (316SS, Monel)
  • 5-way manifold valve (316SS, Monel)