Assembled FRL Series MD
Modular assembly
The various functions can be connected by means of intermediate junctioning cartridges.
The regulator and the valves can be adjusted so as to have the regulation devices or the actuation in front or lower position.
There are different types of wall mounting available.Thanks to the solution adopted for the pneumatic connection, it is possible to equip the same element with interchangeable cartridges that can either be threaded, or with an integrated super-rapid fitting, both types available in different sizes. Intermediate cartridges can be also integrated to join multiple functions or with derivation to draw air.
General Data
| Construction | Modular, Compact |
| Materials | See catalogue pages referring to the single component |
| Ports | With interchangeable cartridges: 1/8, 1/4 and 3/8 threaded or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm |
| Fixing | Vertical in-line; Wall-mounting by means of through holes in the body or with a support bracket; Panel mounting |
| Operating temperature | -5°C ÷ 50°C up to 16 bar (according to the single component characteristics) |
Coding Example
| MD | 1 | – | V01 | F000 | R000 | L00 | V16 | – | 8 | – | LH |
| MD | SERIES | ||
| 1 | ( 1 ) | DIMENSION: 1 = 42 mm | |
| V01 | ( 2 ) [ * ] | MODULE + [ * ] (to configure the modules, see the single components pages): F… = Filter FC… = Coalescing filter FCA… = Activated carbons filter R… = Pressure regulator L… = Lubricator FR… = Filter-Regulator V… = Lockable isolation valve AV… = Soft start valve B… = Take-off blockThe following ACCESSORIES can be added after every single module: REGULATOR, FILTER-REGULATOR AND MANIFOLD REGULATOR LOCKABLE ISOLATION VALVE …V01 / V16 / V36 SOFT START VALVE AND 5-WAY TAKE-OFF BLOCK INTERMEDIATE JOINING CARTRIDGE WITH DERIVATION (MD1-B) | LOCKABLE ISOLATION VALVE…V16 +A35 = U7H (coils 12V DC) +A36 = U77 (coils 24V DC) +A37 = U79 (coils 48V DC) +A38 = U7K (coils 110V AC) +A39 = U7J (coils 230V AC) +A40 = G7H (coils 12V DC) +A41 = G77 (coils 24V DC) +A42 = G79 (coils 48V DC) +A43 = G7K (coils 110V AC) +A44 = G7J (coils 230V AC) |
| F000 | ( 3 ) | see MODULE (2) + [ * ] | |
| R000 | ( 3 ) | see MODULE (2) + [ * ] | |
| L00 | ( 3 ) | see MODULE (2) + [ * ] | |
| V16 | ( 3 ) | see MODULE (2) + [ * ] | |
| 8 | ( 4 ) | PORTS (IN – OUT)**: = without cartridges 1/8 = G1/8 1/4 = G1/4 3/8 = G3/8 6 = tube Ø6 8 = tube Ø8 10 = tube Ø10 | |
| LH | ( 5 ) | FLOW DIRECTION: = from left to right (standard) LH = from right to left |
nx = the combination “(3) + (*)” can be repeated an odd (“n”) number of times
** NOTE: if the inlet (IN) cartridge is different from the outlet (OUT) cartridge, both dimensions shall be indicated. Example: MD1-V01F000R000-3/8-8