Pressure regulators Series MX

MX2 ports: G3/8, G1/2, G3/4 – MX3 ports: G3/4, G1
Manifold ports: G1/2 (MX2 only)
Modular – Available with built-in pressure gauges or ports for gauges

The availability of constant values of the secondary pressure ensures performance optimization and energy saving. The tamper-proof system allows to adjust pressure safely with primary pressure compensation. All reducers are equipped with an integrated locking system and built-in pressure gauges for a more compact product. The regulators Series MX are suitalbe also for panel mountings.

The Series MX has been realized to offer a multi-sector solution that guarantees saving in terms of installation time, space and costs.

A special configurator, available on Camozzi website at http://shop.camozzi.com (sec. Configurators), allows the customer to choose the most suitable solution for his
application, selecting single components or by configuring assembled FRLs.

General Data

ConstructionModular, compact, diaphragm type
MaterialsSee TABLE OF MATERIALS on the following page
PortsMX2: G3/8 – G1/2 – G3/4 – MX3: G3/4 – G1
Manifold regulator: G1/2 (MX2 only)
MountingVertical in-line, wall-mounting (by means of clamps), panel mounting
Operating temperature-5°C ÷ 50°C up to 16 bar (with the dew point of the fluid lower than 2°C at the min. working temperature)
-5°C ÷ 60°C up to 10 bar (with the dew point of the fluid lower than 2°C at the min. working temperature)
Inlet pressure0 ÷ 16 bar
Outlet pressure0,5 ÷ 10 bar (standard)
0,5 ÷ 4 bar
0,5 ÷ 7 bar (MX2 only)
Overpressure exhaustWith relieving (standard) or without relieving
Nominal flowSee FLOW DIAGRAMS on the following pages
FluidCompressed air
Pressure gaugeBuilt-in pressure gauge (standard)
with G1/4 port (MX3 only) or G1/8 port (MX2 only)

Coding Example

MX23/8R004LH
MXSERIES
2SIZE
2 = G3/8 – G1/2 – G3/4
3 = G3/4 – G1
3/8PORTS
3/8 = G3/8
1/2 = G1/2
3/4 = G3/4
1 = G1
RTYPE OF REGULATOR
R = Pressure regulator
M = Manifold pressure regulator (MX2 – G1/2 only)
0OPERATING PRESSURE (1 bar = 14,5 psi)
0 = 0,5 ÷ 10 bar (standard)
4 = 0,5 ÷ 4 bar
7 = 0,5 ÷ 7 bar (MX2 only)
0DESIGN TYPE
0 = Relieving (standard)
1 = Without relieving
2 = Relieving, with by-pass valve (only regulator)
3 = Without relieving, with by-pass valve (only regulator)
4PRESSURE GAUGE
0 = Without pressure gauge (with threaded port for gauges)
2 = With built-in pressure gauge 0-6 and working pressure 0,5 ÷ 4 bar
3 = With built-in pressure gauge 0-10 and working pressure 0,5 ÷ 7 bar (MX2 only)
4 = With built-in pressure gauge 0-12 and working pressure 0,5 ÷ 10 bar (standard)
LHFLOW DIRECTION
= From left to right (standard)
LH = From right to left

Download