Proportional pressure regulator with CoilVision technology Series PRE

Two sizes available: PRE1 and PRE2
Ports G1/8 – G1/4 – G3/8 – 1/4NPTF

The Series PRE proportional pressure regulator is equipped with a new technology, CoilVision, which constantly monitors the operation of the solenoids in the regulator to assess their health status.

All data generated by the regulator can be transmitted wirelessly, for logging, aggregation and analysis and can be viewed through the UVIX software, downloadable from the Camozzi Catalogue website.

The Series PRE is available in two sizes and in different configurations, including IO-Link connectivity. As well as the standard options with and without display, there is a version with an integral exhaust valve, which enables the system to exhaust even without a power supply.

A manifold version enables the control of several outlets with only one inlet, while a version with an additional external sensor connection enables pressure control at any point in the system.

General Data

Standard of referenceCE; RoHS; UL-CSA
Controlled quantityPressure
Number of ways3
Flow (Qn)PRE104 – 1100 Nl/min PRE238 – 4600 Nl/min
FluidFiltered and non-lubricated compressed air of class [7:4:4] according to ISO 8573.1. Inert gases and oxygen
Min. and max. regulated pressure [bar]0 – 1 bar (0-14,5 PSI)(B) 0,05 – 10,3 bar (0,72-150 PSI)(D) 0,05 – 6 bar (0,72-87 PSI)(F)
0,03 – 4 bar (0,43-58 PSI) (E) 0,05 – 7 bar (0,72-101,5 PSI) (G)
Maximum inlet pressure2 bar (B) 5 bar (E) 11 bar (D); (G) ed (F)
External sensor (optional)Input signal 0-10 V DC or 4-20 mA
Resolution (% FS)0,3 (Size 1) 0,6 (Size 2)
Fluid temperature (min and max °C)0 – 50 °C
Environmental temperature (min and max °C)0 – 50 °C
Pneumatic portsG1/8 – G1/4 – G3/8 – 1/4 NPTF
MaterialsBody: aluminium
Cover: technopolymer
Seals: NBR or FKM
Supply voltage (V)24 V DC
Command signal0-10V (2); 4-20 mA (4); 5 bit Digital (D); IO-Link (I)
Hysteresis (% FS)0,5% (size 1) 0,7% (size 2)
Power consumptionFrom a minimum of 105 to a maximum of 250 mA (see the product manual for further details)
Type of electrical connectionM12 5 Pin Male (IO-Link)
M12 8 Pin Male (Analog and PreSet)
M12 12 Pin Male (version with external sensor)
IP protection classIP65
Repeatability (% FS)0,4
Linearity (% FS)0,4
ModularityWith Series MD
PRE in IO-Link versionV1.1 according to standard IEC 61131-9 / 61131-2
Feedback signal0-5 V DC and 4-20 mA (always present in the version with analog command signal (2) (4))

Coding Example

PRE104DD5I2E000DOX1
PRESERIES
1SIZE
1 = Size 1
2 = Size 2
04CONNECTION PORT
04 = G1/4
38 = G3/8 (only size 2)
M4 = G1/4 Manifold
14 = NPTF 1/4 (only size 1)
N4 = 1/4 NPTF Manifold
08 = G1/8 (only size 1)
M8 = G1/8 Manifold (only size 1)
DDISPLAY
E = Without display
D = With display (only with command signal 2,4 or D)
DWORKING PRESSURE (1 bar = 14,5 psi)
B = 0-1 bar
E = 0-4 bar
F = 0-6 bar
G = 0-7 bar
D = 0-10,3 bar
2 = External sensor 0-10 o 4-20 mA. The external sensor is not included in the controller, it must be purchased separately
5VALVE FUNCTION
5 = 3 way standard
6 = Integrated exhaust valve (maximum working pressure B, E or G)
7 = 3 way (connection 3 transportable, optional for size 1, standard for size 2)
8 = Integrated exhaust valve (port 3 transportable, optional for size 1, standard for size 2. Maximum working pressure B, E or G)
IPILOT SUPPLY
I = Internal
E = External
2COMMAND SIGNAL
2 = 0-10 V
4 = 4-20 mA
D = 5 bit Preset for 32 different pressure values
I = IO-Link (only without display)
EDIGITAL OUTPUT SIGNAL
E = Error signal (only with input signal 2, 4, D)
P = Pressure switch (only with input signal 2, 4, D)
W = Window (only with input signal 2, 4, D)
N = Without digital output (only with IO-Link version)
00CABLE LENGTH
00 = No cable
2F = 2mt straight unshielded
2R = 2mt 90° cable unshielded
5F = 5mt straight unshielded
5R = 5mt 90° cable unshielded
2FC = 2mt straight shielded
2RC = 2mt 90° shielded
5FC = 5mt straight shielded
5RC = 5mt 90° shielded
0DDIAGNOSTIC ACCESSORIES
= Without diagnosis (only with input signal 2, 4, D)
0D = Basic diagnostics (only with input signal 2, 4, D)
0W = Wireless diagnostics (only with input signal 2, 4, D)
DW = Wireless diagnostics + CoilVision® (only with input signal 2, 4, D))
1D = IO-Link + CoilVision® diagnostics (only with IO-Link version)
OX1USE WITH OXYGEN
= Not suitable for use with oxygen
OX1 = For use with oxygen – cleanliness level according to ASTM G93-03 Standard Level E
Version suitable to be used with oxygen.
With a working pressure of Max 6 Bar, available both with internal and external pilot supply; with all other versions only with external pilot supply.”

Download