Direct acting solenoid valves Series KN and KN High Flow

3/2-way – Normally Closed (NC) and Normally Open (NO)
3/2-way – Universal (UNI)
The Series KN directly operated solenoid valves are available also in the high flow version (KN High Flow).

Thanks to its low energy consumption and to its compact design, the KN miniaturized solenoid valve can be used in industrial and scientific applications.

General Data

TECHNICAL FEATURES
Function3/2 NC – 3/2 NO – 3/2 UNI
OperationDirect acting poppet type
Pneumatic connectionsOn subbase with ISO 15218 interface
Orifice diameter0,65 … 1,1 mm
Flow coefficient kv (l/min)0,15 … 0,39
Operating pressure0 ÷ 3 … 7 bar
Operating temperature0 ÷ 50 °C
FluidFiltered compressed air, unlubricated, according to ISO 8573-1:2010 class [3:4:3], inert gas
Response timeON <10 ms – OFF <10 ms
Manual overrideMonostable
InstallationIn any position
MATERIALS IN CONTACT WITH THE MEDIUM
BodyPBT
SealsNBR – FKM
Internal partsStainless steel
ELECTRICAL FEATURES
Voltage5 … 24 V DC – other voltages on demand
Voltage tolerance±10%
Power consumption1,3/0,25 … 4/1 W (inrush/holding)
Duty cycleED 100%
Electrical connectionConnector mod. 121-8…
Protection classIP50

Special versions available on demand.

Coding Example

KN000303K13
KNSERIES
0BODY DESIGN
0 = Single valve
00NUMBER OF POSITIONS
00 = Interface
3NUMBER OF WAYS – FUNCTIONS
3 = 3/2-way – NC
4 = 3/2-way – NO
7 = 3/2-way – UNI
0PORTS
0 = ISO 15218 on subbase or manifold
3ORIFICE DIAMETER
3 = Ø0,65 mm
5 = Ø1,1 mm – only for NC version with minimum pressure required to operate
6 = Ø1,1 mm
KMATERIALS
F = PBT body – FKM poppet – FKM other seals
K = PBT body – FKM poppet – NBR other seals
1ELECTRICAL CONNECTION
1 = 90° connection with protection and led
B = In-line connection with protection and led
3VOLTAGE – POWER CONSUMPTION
2 = 12 V DC – 1,3/0,25 W
3 = 24 V DC – 1,3/0,25 W
5 = 5 V DC – 4/1 W
7 = 12 V DC – 4/1 W
8 = 24 V DC – 4,1 W
FIXING
= Fixing screws for plastic
M = Fixing screws for metal
USE WITH OXYGEN:
= Not suitable for use with oxygen
OX2 = per utilizzo con ossigeno – livello di pulizia secondo normativa ASTM G93-03 Livello B