Overview
Swirl flowmeters are used for highly accurate measurement of the flow of gases, liquids and steam over a wide range of temperatures in almost any application. Swirl meters are ideal for use on low viscose liquids, demineralized water, and for direct, cost-effective steam mass flow.
SwirlMaster FSS450 is the advanced version with additional analog input for mass or energy flow measurement, available with integral or remote transmitter with up to 30 m (98 ft.) cable length. Because of the optional inputs, discrete flow computers are no longer needed in many applications.
Standard features:
- HMI for easy meter set up
- Analog 4 … 20 mA input
- Integrated RTD for temperature compensation and saturated steam mass flow calculation
- Digital outputs for pulses, frequency, and alarm signalization
Optionally available:
- Remote transmitter with up to 30 m (98 ft.) cable length
- Stainless steel transmitter housings
- SIL 2
Data
General specifications:
- Easy assembly
– Only the shortest possible straight pipe lengths are required
– Measuring ranges have been well adopted to the flow rates - Intuitive operation
– Easy Set-up function
– Clear text display
– Meter configuration through the front glass with closed cover - Accuracy for liquids, gases and steam
– +/- 0.50% of rate - Process connection / meter sizes
– Flange design / DN 15 to 400 (1/2 to 16 in.) - Approvals for explosion protection
– ATEX, IECEx, cFMus, NEPSI - SIL2-certified in accordance with IEC 61508
- Output / communication
– 4 to 20 mA / HART 7 - Optional binary output
– For use as a limit switch, pulse output or frequency output - Optional input from field
– Pressure, temperature, methane content, density gas analyzer - Integrated flow measurement computer functionality
– Gas standard volume and mass flow
– Vapor mass flow
– Direct energy calculation for vapor and water
– Natural gas calculation in accordance with AGA / SGERG standards