Overview
Product | Electromagnetic flowmeter |
Model | FMC240 |
Diameter nominal | DN15~DN1000 |
Nominal pressure | DN15 – DN250, PN ≤1.6MPa |
DN300 – DN1000, PN ≤1.0MPa | |
Accuracy | ±0.5% F.S. (Flow speed > 0.5m/s); ±0.5% F.S.±2mm/s(Flow speed <0.5m/s) |
Repetitiveness | 0.16% |
Liner material | Neoprene (CR), Polyurethane (PU), PTFE (F4), PFEP (F46), PFA |
Electrode material | 316L Stainless Steel, Hastelloy C, Hastelloy B, Ti, Ta, Pt |
Medium temperature | Neoprene: -10…+70℃ Polyurethane: -10…+60℃ PTFE/FEP: -10…+120℃ PFA: -10…+120℃ |
Power supply | 220VAC, 24VDC |
Structure type | Compact type, Remote type |
Ingress protection | IP65, IP68(remote type only) |
Product standard | JB/T 9248-2015 |
Image