Service intended

P840 series are specially designed for the ultra-high purity gas distribution system used in a semiconductor, electronic, medical, biotechnology and pharmaceutical industry.

Nominal diameter50 mm (2″)
Switch point accuracy±2.0 % of full scale
Scale range0 ~ 28 MPa
Working pressureSteady pressure : 75 % of full scale value
Fluctuating pressure : 67 % of full scale value
Working temperatureAmbient : -20 ~ 65 °C
Fluid : Max. 100 °C
Temperature effectAccuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately
±0.4 % per 10 ℃ of full scale

Standard features

Electrical

Connection26 AWG, PVC
6 feet (2 m)
Maximum switching current0.5 amps AC/DC noninductive load
Maximum power10 W/DC, 12 VA/AC
Maximum switching voltage28 V AC/DC

© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.