Service intended

P611 to P612 series are designed to measure differential pressure from 5 kPa ro 1.5 MPa at Max. working pressure up to 25 MPa.
P611 to P612 series are designed to control and alarm for differential pressure, providing right time to replace air and sluge filter during the process.

Nominal diameter100 and 160 mm
Accuracy±1.0% of full scale
±1.5% or ±1.6% of full scale
Scale range (MPa, kPa, bar)0~30 kPa to 0~50 kPa
0~0.1 MPa to 0~1.5 MPa
Max. Working pressure (Static pressure)25 MPa
Working temperatureAmbient : -20~65°C
Fluid : Max. 100°C
Degree of protectionEN60529/IEC529/IP65
Temperature effectAccuracy at temperature above and below the reference
temperature (20℃) will be effected by approximately
±0.5% per 10℃ of full scale

Standard features

Pressure connectionStainless steel (316SS)
ElementSingle Bellows
Stainless steel (316L SS)
CaseStainless steel (304SS)
CoverStainless steel (304SS)
Bayonet type
WindowPolycarbonate
DialWhite aluminium with black graduations
Conduit connectionM20 x 1.5P
ContactContact rating: AC 230 V 0.12 A / 110 V 0.24A
DC 220 V 0.1 A / 110 V 0.2 A
PointerBlack painted aluminium alloy
Process connection¼” NPT(F)
½” NPT(F) at 3-way and 5-way manifold valve
Standard accessoriesMounting bracket for 2″ pipe
mounting with silver gray finished steel
Optional
  • Remote seal
  • Mounting bracket with 316SS for 2″ pipe mounting
  • 3-way manifold valve (316SS, Monel)
  • 5-way manifold valve (316SS, Monel)

Download

DATA SHEET