Service intended

P257 series are made with a solid plate wall and a blow-out back. Its stainless steel case and cover have a good appearance. It has the excellent proof against corrosion and chemical attack.

Nominal diameter63, 100 and 160 mm
AccuracyP2572 (63 mm) : ±1.6 % of full scale
P2574 (100 mm) and P2576 (160 mm) : ±0.5 % of full scale
±1.0 % of full scale
Scale range (MPa, kPa, bar)63 mm : -0.1 ~ 0 to 0 ~ 100 MPa
100 and 160 mm : -0.1 ~ 0 to 0 ~ 200 MPa
Working pressureSteady : 75 % of full scale (63 mm)
100 % of full scale (100 and 160 mm)
Over range protection : 130 % of full scale
Working temperatureAmbient : -40 ~ 65 ℃
-20 ~ 65 ℃ (With glycerin filling)
-40 ~ 65 ℃ (With silicone filling)
Fluid : Max. 200 ℃
Max. 100 °C (With glycerin filling)
Max. 100 ℃ (With silicone filling)
Degree of protectionEN60529/IEC529/IP67
Temperature effectAccuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately
±0.4 % per 10 ℃ of full scale

Standard features

Pressure connectionStainless steel (316SS)
ElementStainless steel (316SS)
63 mm : <6 MPa : C type bourdon tube
≥6 MPa : Helical type bourdon tube
100 and 160 mm : <10 MPa : C type bourdon tube
≥10 MPa : Helical type bourdon tube
CaseStainless steel (304SS)
CoverStainless steel (304SS) Bayonet type
Blowout protectionSolid front Blow-out back
WindowLaminated safety glass
MovementStainless steel
DialWhite aluminium with black graduations
PointerBlack painted aluminium alloy
Process connection63 mm : ⅛”, ¼” PT, NPT and PF
100 and 160 mm : ¼”, ½”, ⅜” PT, NPT and PF
CertificatesPressure equipment directive (2014/68/EU)-Annex III Module H
ATEX II 2G Ex h IIC T6…T1 Gb
ATEX II 2D Ex h IIIC T85°C….T450°C Db
OptionZero adjustable pointer
(Only available with diameter 100 and 160 mm)
Zero adjustment (External) : 100 and 160 mm
Pressure connection and element : Monel
(Only available with diameter 100 and 160 mm)

© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.

Download

CATALOG

MANUAL

DRAWING

IP TEST_P257

IP TEST_P721+P257

Certificates