APT9000L Series

The APT9000L Series is a digital differential pressure transmitter designed for industrial level measurement applications.
The APT9000L can be configured to provide integrated solutions for a broad range of pressure and flow measurement applications.

Features

  • Updating time of output current in 200 ms
  • Improved performance, increased accuracy and greater stability
  • Two years stability of 0.15%
  • Accuracy of 0.075%
  • Parameter setting by keypad directly
  • 4-20 mA output plus direct digital  HART communication
  • Automatic zero calibration by push-button
  • Explosion proof and weather proof housing

Specification

Process Fluid:Liquid, Gas, Vapor
Application:Liquid Level, Differential Pressure,
Gauge Pressure, Absolute Pressure
Measuring Range:0-6.0 kPa~0-40 kPa (Minimum)
:0-4.0 MPa~0-20.0 MPa (Maximum)
Turndown Ratio:100:1
Accuracy:+/-0.075% of span
Stability:+/-0.15% of URL for 2 years
Working Temperature:-40~250 °C
Max. Pressure:40 MPa (Dependent on flange rating)
Material
Flange / Adapter:Carbon Steel / Stainless Steel 304 /
Stainless Steel 316
Diaphragm:Stainless Steel 316L / Hastelloy B /
Hastelloy C / Monel / Tantalum
Extented Tube:Stainless Steel 316
Bolts & Nuts:Carbon Steel / Stainless Steel 316
Name / Tag Plate:Stainless Steel 304 / Stainless Steel 316
Converter Housing:Low copper cast aluminum alloy with
polyurethane, light blue paint
Fill Fluid:Silicone Oil / High Temperature Silicone Oil
Fluorine Oil / Vegetable Oil
Protection Class:IP67 (Standard)
:Intrinsically Safe, Eex ia IIC T5 (Standard)
:Explosion Proof, Ex db IIC T6
Display:5 Digits programmable & 0-100% Bargraph
Display Unit:Standard 22 different engineering unit
5 Digits programmable for special unit
Keypad:3 Internal keys for programming and
output setting
Current Output:4-20 mA (2-Wire)
with Hart Signal (Compatible)
Load:Rohm= (VDC-9) * 50
Power Supply:9-36 VDC
Digital Communication:Hart Protocol
Damping:0-32 Seconds
Response Time:100 ms
Turn on Time:2 Seconds with minimum damping
Zero Calibration:Automatic calibration by push-button
Cable Entry:1/2″ NPT (Female) / M20 Conduit Threads
Temperature Effect:+/-0.18%~+/-0.5% of span per 20 °C
EMI / RFI Effect:Follow SAMA PMC 33.1 from 20-1000 MHz
and for field strengths up to 30 V/m
Process Connection
High Pressure Side:1-1/2″, 2″, 3″, 4″ Flanges
ANSI / DIN / JIS / Tri-Clamp
Extended Diaphragm:2″, 4″, 6″ length
Low Pressure Side:1/4″-18 NPT , 1/2″-14 NPT
Ambient Temperature:-25~85 °C
Dimensions:102 mm (W) * 188 mm (H) * 189 mm (D)
Weight:8-15 kg

Download