Extra Information
Nominal diameter | 100 and 160mm |
Accuracy | ±1.0% of full scale |
Scale range (MPa, kPa, bar) | 0 ~1 kPa to 0 ~ 40 kPa (Flange 150 mm) 0 ~ 50 kPa to 0 ~ 2.5 MPa (Flange 100 mm) |
Working pressure | Steady : Full scale value Fluctuating : 90% of full scale value |
Over range protection | Overpressure safety 500% of full scale value, however Max. 4 MPa |
Working temperature | Ambient : -20 ~ 65 °C Fluid : Max. 100°C |
Degree of protection | EN60529/IEC529/IP67 |
Temperature effect | Accuracy at temperature above and below the reference temperature (20℃) will be effected by approximately ±0.4% per 10℃ of full scale |
Standard Features
Pressure connection and under flange | Material : 304SS, 316SS, 316L SS |
Upper flange (Gauge side) | Material : 304SS, 316SS |
Diaphragm material | ≤40 kPa Stainless steel (316Ti SS) >40 kPa Duratherm 600 |
Case | Stainless steel (304SS) |
Cover | Stainless steel (304SS) Bayonet type |
Window | Safety glass : Only available with diameter 100 mm Polycarbonate : 100 and 160 mm |
Movement | Stainless steel |
Dial | White aluminium with black graduations |
Pointer | Black painted aluminium alloy |
Conduit connection | M20 x 1.5 |