Extra Information

Nominal diameter 63, 100 and 160 mm
Accuracy P2592 (63 mm) : ±1.6 % of full scale
P2594 (100 mm) and P2596 (160 mm) : ±1.0 % of full scale
Scale range (MPa, kPa, bar) 63 mm : -0.1 ~ 0 to 0 ~ 40 MPa
100 and 160 mm : -0.1 ~ 0 to 0 ~ 100 MPa
Filling liquid Glycerine
Working pressure Steady : 75 % of full scale (63 mm) 100 % of full scale (100 and 160 mm)
Over range protection : 130 % of full scale
Working temperature Ambient : -20 ~ 60 °C (With glycerin filling) -40 ~ 60 °C (With silicone filling)
Fluid : Max. 60°C
Degree of protection EN60529/IEC529/IP67
Temperature effect Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately
±0.4 % per 10 ℃ of full scale

Standard Features

Pressure connection Brass
Element Brass Model : P2594 (100 mm) and P2596 (160 mm)
<10 MPa : C type bourdon tube
≥10 MPa : Helical type bourdon tube with 316SS
Model : P2592 (63 mm)
<6 MPa : C type bourdon tube
≥6 MPa : Helical type bourdon tube
Blowout protection Back, Rubber disc for 100 and 160 mm
Top, Rubber disc for 63 mm
Case Stainless steel (304SS)
Cover Stainless steel (304SS)
Bayonet type
Window Laminated safety glass
Movement 63 mm : Brass
100 and 160 mm : Stainless steel
Dial White aluminium with black graduations
Pointer Black painted aluminium alloy
Process connection 63 mm : ¼" PT, NPT and PF
100 and 160 mm : ⅜", ½" PT, NPT and PF
Option Zero adjustable pointer
(Only available with diameter 100 and 160 mm)
Silicone filling

Please click on the picture to preview