Service intended

P940 series pressure switches are micro contact type, and these are suitable for corrosive fluids and high pressure measurements. Dead band is fixed.

Nominal diameterRefer to dimension drawing
Repeatability±1.0 % of adjustable range
Adjustable setting range (MPa, kPa, bar)-0.1 ~ 0 to -0.1 ~ 2.5 MPa
0 ~ 0.1 to 0 ~ 35 MPa
Dead bandFixed
One SPDT : Approx. 5 % adjustable range
Two SPDT : Approx. 10 % of adjustable range
Working temperatureAmbient : -20 ~ 65 °C
Fluid : Max. 100 °C

Standard features

Pressure connectionStainless steel (316SS)
ElementStainless steel (316SS)
Case and coverALDC 12.1
Silver gray painted
ContactMicro contact type
One SPDT or two SPDT
Contact ratingSPDT contact rating
AC 125 V / 250 V, 15 A
DC 125 V, 0.4 A for resistance load
DC 125V, 0.03 A for resistance load
Conduit connection½” PF (Single setpoint) P941
¾” PF (Dual setpoint) P942
Process connection⅜”, ½” PT, NPT and PF

© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.