Service intended

P501 and P502 seriese are designed for a local reading of measured pressure and equipped with the inductive contact block which allows all the combinations of contact to be used. The contact block is mounted on the dial. The windows is fitted with a knob for external adjustment of the setpoints.

Nominal diameter100 and 160 mm
Accuracy±1.0 % of full scale
Scale range (MPa, kPa, bar)0 ~ 1 kPa to 0 ~ 40 kPa (Flange 150 mm)
0 ~ 50 kPa to 0 ~ 2.5 MPa (Flange 100 mm)
Working pressureSteady : Full scale value
Fluctuating : 90 % of full scale value
Working temperatureAmbient : -20 ~ 65 °C
Fluid : Max. 100 °C
Degree of protectionEN60529/IEC529/IP67
Temperature effectAccuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately
±0.4 % per 10 ℃ of full scale

Standard features

Pressure connection and under flangeMaterial : 304SS, 316SS and 316L SS
Upper flange (Gauge side)Material : 304SS, 316SS
Diaphragm material≤40 kPa Stainless steel (316Ti SS)
>40 kPa Duratherm 600
CaseStainless steel (304SS)
CoverStainless steel (304SS) Bayonet type
WindowSafety glass : Only available with diameter 100 mm
Polycarbonate : 100 and 160 mm
MovementStainless steel
DialWhite aluminium with black graduations
PointerBlack painted aluminium alloy
Conduit connectionM20 x 1.5
CertificatesNEPSI Ex ia IIC T6 Ga
Tamb = -25 ~ 56 ºC
OptionExternal zero adjustable

© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.

Download

CATALOG

MANUAL

HOW TO ORDER

Certificates