Overview
With no up or downstream piping requirements the compact flowmeters can be installed in the tightest spaces, enabling applications not possible before.
The FCH100 series delivers:
- EHEDG, hygienic certification
- Superior accuracy and speed for filling applications
- Full parameter access with up to 115 kBaud
- Aluminum housing or all stainless steel solution
- DTM based diagnostic and operability functions
The sensor delivers:
- Multivariable measurement of mass flow, density and temperature in one device
- Low pressure drop save 25 % on pump energy costs compared to other brands
- Wide measurement span in a single meter
FCH150 adds:
- DensiMass: High accuracy concentration measurement, watercut and net-oil computing as well as net-mass and net-volume measurement
- FillMass: Filling application software with integrated precounter, over- and underfill correction and contact output for valve control
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2 - Wetted materials
– 1.4404 / 1.4435 (316L) - Accuracy for liquids
FCH130
– Mass and volume: 0.4 % o. r. / 0.25 % o. r.
– Density: 10 g/l
FCH150
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCH130
– -50 to 160 °C (-58 to 320 °F)
FCH150
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 2 digital out (pulse, frequency, contact)
– Modbus - Power supply
– 11 to 30 V DC