Main features

  • Controller
  • 30, 60, 80kW solid state relay
  • Current transformers

Available resources

Brochure
Brochure Power Control
Gefran product range brochure

Fieldbus Configuration files
GFX4 – GFXTermo4 – GFX4-IR – EDS Configuration files (Devicenet)
EDS Configuration file for GFX4IR (opzione E2)
GFX4/GFXTERMO4/GFX4-IR GSD files Ver.P01
GFX4/GFXTERMO4/GFX4-IR GSD files Ver.P02
GFX4/GFXTERMO4/GFX4-IR GSD files Ver.P03
GFX4/GFXTERMO4/GFX4-IR GSD files Ver.P04
GFX4/GFXTERMO4/GFX4-IR GSD files Ver.P05
GFX4-IR GSD files Ver.HP01
GEFRAN Profinet V2.00 (for Step 7 / CPU3xx)
EDS CONFIGURATION FILE FOR GFX4-IR (OPZIONE E5)
GFX4-IR address map
EDS CONFIGURATION FILE FOR GFX4-IR (OPZIONE E8)
GFX4/GFXTERMO4/GFX4-IR GSD FILES VER.P06
GFX4/GFXTERM04/GFX4IR EDS files Ver. C05
GFX4/GFXTERM04/GFX4IR EDS files Ver. C06
GFX4/GFXTERM04/GFX4IR EDS files Ver. HC02 (“High performance”)
GFX4/GFXTERM04/GFX4IR EDS files Ver. HC03 (“HIGH PERFORMANCE”)
GSDML configuration file for GFX4-IR (opzione E4)

Datasheet – Fieldbus
GFX4/GFXTERM04-Profibus datasheet
GFX4/GFXTERM04-CANopen datasheet
GFX4/GFXTERM04-DeviceNet datasheet
GFX4/GFXTERM04-Modbus datasheet
GFX4/GFXTERM04-EtherCAT datasheet
GFX4/GFXTERM04-Modbus TCP datasheet
GFX4/GFXTERM04/GFX4-IR/GFW Ethernet IP Datasheet
GFX4-GFXTermo4-GFX4-IR-PROFINET Data Sheet

Software
GFX4/GFXTERM04/GFX4IR EDS files Ver. C04 (“BRIDGE”)
GFX4/GFXTERM04/GFX4IR EDS files Ver. C01 (“BRIDGE”)
GFX4/GFXTERM04/GFX4IR EDS files Ver. C02 (“BRIDGE”)
GFX4/GFXTERM04/GFX4IR EDS files Ver. C03 (“BRIDGE”)
GFX4/GFXTERM04/GFX4IR EDS files Ver. HC01 (“High Performance”)

Datasheet
GPX4-IR datasheet

User Manual
HW – Installation and Operation Manual
GF_EXPRESS README
GF_eXpress UserGuide
GFX4-IR – Programming and Configuration

User Manual – Fieldbus
MSW ETHERNET IP_E1 (obsolete version) – GFX4/GFX4-IR/GFXTermo4
MSW ETHERNET IP (obsolete version) – GFX4-IR
MSW ETHERNET IP E8 – GFX4 – GFXTERM04 – GFX4-IR
GFX4-IR PROFINET – User manual
GFX4/GFX4IR/GFXTHERMO4 (ETHERCAT) – Installation and operational manual
GFX4/GFXTERMO/GFX-IR CANopen – Configuration and programming manual
GFX4/GFXTERMO/GFX-IR Profibus-Programming and Configuration

Software – Library
Step 7 Library 1.00
Step 7 Library 2.00

Catalogue
4.0 plastic application catalogue

Quick Start Guide
Quick start guide – GFX4IR

Configuration Software
CATALOG VER. 3.0.0
GF_EXPRESS VER 2.1.54

Certifications
EU Conformity Declaration 2019 – GFX4IR
SCCR 100KA – GFX4, GFX4-IR and GFW
UK Conformity declaration – GFX4IR
EAC CERTIFICATION
Ethernet IP certification – ODVA – GFX4-IR («E8»)
Profinet Certification 2024 – GFX4-IR
Ethernet IP Certification – Ethernet IP – ODVA – GFX4-IR («E5»)
UL Certifications – UL – GFX4-IR serie

Technical specifications

Overview

GFX4-IR is a four independent loop controller, designed to manage electrical power.

GFX4 is a compact unit bounding different technological elements like:

  • controller
  • solid state relay
  • current transformers
  • fuses-holders (option)

The final result is a cost saving in terms of space and cabling.

The GFX4-IR is managed by a microprocessor that independently controls the four control loops and also runs functions specifically designed to manage singlephase and 3-phase loads, with low and high temperature coefficient, medium and short wave infrared lamps, and transformer primary circuits.

The multiple activation methods are all software-configurable, and include:

  • Zero crossing with constant cycle time for conventional loads
  • Burst firing with variable cycle time for systems with low thermal inertia, medium wave IR lamps
  • Single cycle for short wave IR lamps with reduced flickering (half single cycle)
  • Phase angle control with current limit for short wave IR lamps, transformer primaries, with assignment of soft start up and soft stop down options with limitation of max. rms current.

GFX4IR runs complete diagnostics of current, voltage, and temperature levels:

Current

  • Total and partial interrupted load alarm
  • “Teach-in” function for self-learning of alarm threshold for interrupted load
  • SCR in short circuit alarm
  • Load in short circuit or in overcurrent alarm
  • Unbalanced 3-phase load alarm

Voltage

  • Phase loss in case of 3-phase configurations
  • Check of correct phase sequence alarm

Temperature

  • Overtemperature alarm

Various feedback functions in the absence of PID control have been developed for complete control of loads in all types of applications:

  • Voltage feedback (V) with current limit
  • Current feedback (I)
  • Power feedback with maximum power limit

Configuration is changed by setting simple parameters with a software tool that guides the user to a correct and safe configuration.

GFX4-IR dialogs with the operator terminals according to the most popular protocols: from the simple and efficient Modbus to (via a second optional fieldbus communication) the by-now indispensable Profibus DP, CANopen, DeviceNet, Modbus RTU, Ethernet Modbus TCP, Ethernet IP.

The product comes with a standard configuration that is simple and quick to modify, for example, to assign different functions to outputs.